CVE-2019-10918

CVSS v3 Score
8.8
High
CVSS v2 Score
9.0
Critical

Vulnerability Description

A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An authenticatd attacker with network access to the DCOM interface could execute arbitrary commands with SYSTEM privileges. The vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires authentication with a low-privileged user account and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.

CVSS:8.8(High)

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Marvell QConvergeConsole 5.5.0.64. Although authentication is required to exploit this vulnerability, ...

CVSS:8.8(High)

This vulnerability allows remote attackers to execute arbitrary code on affected installations of Commvault CommCell 11.22.22. Although authentication is required to exploit this vulnerability, the ex...

CVSS:8.8(High)

Govee Home app has unprotected access to WebView component which can be opened by any app on the device. By sending an URL to a specially crafted site, the attacker can execute JavaScript in context o...

CVSS:8.8(High)

Voltronic Power ViewPower USBCommEx shutdown Exposed Dangerous Method Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installation...

CVSS:8.8(High)

D-Link D-View queryDeviceCustomMonitorResult Exposed Dangerous Method Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installation...

CVSS:8.8(High)

D-Link D-View execMonitorScript Exposed Dangerous Method Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of D-Link D...