CVE-2017-2684

CRITICAL Year: 2017
CVSS v3 Score
9.0
Critical
CVSS v2 Score
6.8
Medium

Vulnerability Description

Siemens SIMATIC Logon prior to V1.5 SP3 Update 2 could allow an attacker with knowledge of a valid user name, and physical or network access to the affected system, to bypass the application-level authentication.

CVSS:9.1(Critical)

A vulnerability was found in libssh's server-side state machine before versions 0.7.6 and 0.8.4. A malicious client could create channels without first performing authentication, resulting in unauthor...

CVSS:8.8(High)

prosody before versions 0.10.2, 0.9.14 is vulnerable to an Authentication Bypass. Prosody did not verify that the virtual host associated with a user session remained the same across stream restarts. ...

CVSS:8.5(High)

It was found that the use of Pipeline: Classpath Step Jenkins plugin enables a bypass of the Script Security sandbox for users with SCM commit access, as well as users with e.g. Job/Configure permissi...

CVSS:9.8(Critical)

Baxter SIGMA Spectrum Infusion System version 6.05 (model 35700BAX) with wireless battery module (WBM) version 16 is remotely accessible via Port 22/SSH without authentication. A remote attacker may b...

CVSS:9.8(Critical)

openshift-ansible before versions 3.9.23, 3.7.46 deploys a misconfigured etcd file that causes the SSL client certificate authentication to be disabled. Quotations around the values of ETCD_CLIENT_CER...

CVSS:9.8(Critical)

An authentication bypass flaw was found in the smart_proxy_dynflow component used by Foreman. A malicious attacker can use this flaw to remotely execute arbitrary commands on machines managed by vulne...